Abstract

EUS-Guided Antegrade Transhepatic Placement of a Self-Expandable Metal Stent in Hepatico-Jejunal Anastomosis

Everson LA Artifon, Adriana Vaz Safatle-Ribeiro, Fávio Coelho Ferreira, Luiz Poli-de-Figueiredo, Samir Rasslan, Francisco Carnevale, José Pinhata Otoch, Paulo Sakai, Michel Kahaleh

Context To demonstrate an EUS-guided biliary drainage in patient with gastrointestinal tract modified surgically. Case report An EUS guided access to the left intra hepatic duct, followed by an antegrade passage of a partially self-expandable metal stent that was removed by using an enteroscope, in one patient with hepatico-jejunal anastomosis. There were no early or delayed complications and the procedure was effective in relieving jaundice until the self-expandable metal stent was removed, 3 months later. A cholangiogram was obtained via enteroscopy, after removal of self-expandable metal stent, and found to be normal. The patient had an uneventful evaluation afterwards. Conclusion The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. EUS-guided biliary drainage is feasible when performed by professionals with expertise in biliopancreatic endoscopy and advanced echo-endoscopy and should be performed currently under rigorous protocol in educational institutions.